The 332 Type Inverted
Bucket Steam Trap is designed for installation in vertical pipe work. With cast iron bodies and bolted cover they are maintainable and
offer a very wide range of capacities.
Limiting Conditions
:
Maximum Body
design conditions
PN
16
PMA -
Maximum Allowable pressure
16 kgf/cm2
TMA -
Maximum Allowable temperature
227°C
Cold
hydraulic pressure test
30 kgf/cm2
Dimensions
(mm):
Size
A
B
Weight ( KG )
1/2 "
165
110
3.5
3/4 "
200
134
5.5
1 "
200
134
5.5
Operating Range:
∆ PMX - Maximum differential pressure 16
kgf/cm2
Sizes and Pipe Connections:
1/2 " , 3/4 " and
1 " screwed (DIN ISO 228).
Materials:
No.
Part
Material
1
Body
G.G.25
2
Gasket
Clingrit
3
Balance Weight
Gray Cast
4
Bucket
S.S. 304
5
Plug
S.S. 304
6
Plug Support
S.S. 304
7
Bolt
S.S. 304
8
Seat
S.S. 316
9
Bonnet
G.G.25
10
Nut
C.S.
11
Bolt
C.S.
Capacities:
Maximum Continual discharge
amount ( l/h)
2
4
6
9
13
16
1/2 "
272
396
432
480
536
590
3/4 "
465
564
672
744
912
1060
1"
504
624
720
876
1176
1376
Note: Traps should be selected for the most appropriate working
pressure differential and not on the basis of load.
Installation:
The trap must be
installed with the body upright so that the bucket is rising and falling
vertically. The inlet should be at the bottom with the trap installed
below the drain point so that a water seal can be maintained around
the open end of the bucket.
How to Order:
Example:1/2" -
332 - Inverted bucket steam trap.
Design and specifications
are subject to change without notice.